How does the ONTAP cluster work? (Part 4)

This article is part of the series How does the ONTAP cluster work? Also previous series of articles How ONTAP Memory work will be a good addition to this one.

Data protocols

ONTAP is considered as a unified storage system, meaning it supports both block (FC, FCoE, NVMeoF and iSCSI) & file (NFS, pNFS, CIFS/SMB) protocols for its clients. SDS versions of ONTAP (ONTAP Select & Cloud Volumes ONTAP) do not support FC, FCoE or FC-NVMe protocols because of their software-defined nature.

Physical ports, VLANs and ifgroups considered as “ports” in ONTAP. Each port can run multiple LIFs. If a port has at least one VLAN, then LIFs can be created only on VLANs, not anymore on the port itself. If a port part of an ifgroup, LIFs can be created only on top of the ifgroup, not on the port itself anymore. If a port part of ifgroup on top of which created one or a few VLANs, LIFs can be created only on top of those VLANs, not on ifgroup or physical port anymore.
It is very common configuration when two ports are part of an ifgroup and a few VLANs created for protocols. Here are two very popular examples, in this examples storage system configured with:

  • SMB for PC users (MTU 1500)
    • Popular example: User home directories
  • SMB for Windows Servers (MTU 9000)
    • Use case: MS SQL & Hyper-V
  • NFS for VMware & Linux Servers (MTU 9000)
    • Use-case: VMware NFS Datastore
  • iSCSI for VMware, Linux & Windows Servers (MTU 9000)
    • Block-deice for OS boot and some other configs, like Oracle ASM

Example 1 is for customers who want to use all of the Ethernet-based protocols, but have only 2 ports per node. Example 2 is more preferable with dedicated Ethernet ports for iSCSI traffic if a storage node have sufficient number of ports.

Notice Example 1, has two iSCSI VLANs A & B, which are not necessary, I would use two, in order to increase number of connections over ifgrp to increase load-balancing but it is up to storage & network admins. Normally each, iSCSI-A & iSCSI-B would use a separate IP subnet. See ifgroup section for the network load-balancing explanation.

VLANs

VLANs in ONTAP allow to separate two IP networks one from another and often used with NFS, CIFS and iSCSI protocols, though multiple IP addresses allowed on a single port or VLAN. A VLAN can be added on a physical Ethernet port or to an ifgroup.

ifgroup

Interface group is a collection of a few ports (typically with the same speed). Ports from a single ifgroup must be located on a single node. An ifgroup provide network redundancy to ethernet. Each ifgroup perceived and used as a physical port. One of the most notable & used type of ifgroup is Dynamic multimode. Dynamic multimode enables LACP protocol on ports so in case one port in a group dies another will be used fully transparently to upper-level protocols like NFS, SMB and iSCSI. Most notable in LACP is the ability to distribute data across links in attempt to equally load all the links in the ifgroup.

Ports starting with latter “e“, means it is a physical port, then number of PCIe bus (0 means on-board ports), and then another latter starting with “a” which represents index of the port on the PCIe bus. While ifgroup (virtual aggregated) port names starts with “a” (can be any latter), then number, and then another latter, for example a1a, to keep same format as physical ports for naming convention, even though number and the ending latter no longer represents anything in particular (i.e. PCIe bus or port position on the bus), but used only as index to distinguish from other ports.

Unfortunately LACP load distribution is far from perfect: the more hosts in network communicate with an ifgroup, the more probability to equally distribute traffic across network ports. LACP uses a single static formula depending on source and destination information of a network packet, there is no intellectual analysis and decision-making as for example in SAN protocols and there is no feedback from lower Ethernet level to upper-level protocols. Also LACP often used in conjunction of Multi-Chassis Ether Channel (vPC is another commercial name) functionality, to distribute links across a few switches and provide switch redundancy, which require some additional efforts from switch configuration and the switches themselves. While on another hand SAN protocols do not need switches to provide this type of redundancy because it done on protocol upper level. This is the primary reason why SMB and NFS protocols developed their extensions to provide similar functionality: to more intellectually and equally distribute load across links and be aware of network path status.

One day these protocols will fully remove necessity for Ethernet LACP & Multi-Chassis Ether Channel: pNFS, NFS Session Trunking (NFS Multipathing), SMB Multichannel and SMB Continuous Availability. Until then we going to use ifgroups with configurations which do not support those protocols.

NFS

NFS was the first protocol available in ONTAP. The latest versions of ONTAP 9 support NFSv2, NFSv3, NFSv4 (4.0 and 4.1) and pNFS. Starting with 9.5, ONTAP support 4-byte UTF-8 sequences in names for files and directories.
Network switch technically is not required for NFS traffic and direct host connection is possible, but network switch is used in all the configurations to provide additional level of network redundancy and be able easier add new hosts when needed.

SMB

ONTAP supports SMB 2.0 and higher up to SMB 3.1. Starting with ONTAP 9.4 SMB Multichannel, which provides functionality similar to multipathing in SAN protocols, is supported. Starting with ONTAP 8.2 SMB protocol supports Continuous Availability (CA) with SMB 3.0 for Microsoft Hyper-V and SQL Server. SMB is a session-based protocol and by default does not tolerate session brakes, so SMB CA helps to tolerate unexpected session loss, for example in case a network port went down. ONTAP supports SMB encryption, which is also known as sealing. Sped up AES instructions (Intel AES NI) encryption is supported in SMB 3.0 and later. Starting with ONTAP 9.6 FlexGroup volume supports SMB CA and thus support MS SQL & Hyper-V on FlexGroup.
Network switch technically is not required for SMB traffic and direct host connection is possible, but network switch is used in all the configurations to provide additional level of network redundancy and be able easier add new hosts when needed.
Here is the hierarchy visualization & logical representation of NAS protocols in ONTAP cluster and corresponding commands (highlighted in grey):

Each NAS LIF can accept NFS & SMB traffic, but usually engineers tend to separate them on separate LIFs.

FCP

ONTAP on physical appliances supports SCSI-based FCoE as well as FC protocols, depending on HBA port speed. Both FC & FCoE are known under a single umbrella name FCP. An iGroup is a collection of WWPN address from initiator hosts which allowed to access storage LUNs. WWPN address is interface on FC or FCoE port. typically you need to add all the initiator host ports to iGroup to allow multipathing work properly. ONTAP uses N_Port ID Virtualization (NPIV) for FC data and therefore require a FC network switch (typically at least two) which also supports NPIV, direct FC connections from host to storage are not supported.
Here is the hierarchy visualization & logical representation of FCP protocols in ONTAP cluster and corresponding commands (highlighted in grey):

Read more about ONTAP Zoning here.

iSCSI

iSCSI is another SCSI-based protocol encapsulated in IP/Ethernet transport. NetApp also supports Data Center Bridging (DCB) protocol for some models, depending on Ethernet port chips. Network switch technically is not required and direct host connection is possible, but network switch is recommended to be able easier add new hosts when needed.
Network switch technically is not required for iSCSI traffic and direct host connection is possible if number of storage ports allows, though network switch can be used to easier add new hosts when needed. Network switch is recommended to have with iSCSI.
Here is the hierarchy visualization & logical representation of iSCSI protocol in ONTAP cluster and corresponding commands (highlighted in grey):

NVMeoF

NVMe over Fabrics (NVMeoF) refers to the ability to use NVMe protocol over existing network infrastructure like Ethernet (Converged or traditional), TCP, Fiber Channel or InfiniBand for transport (as opposite to run NVMe over PCIe without additional encapsulation). NVMe is SAN block data protocol. In contrast to NVMe (just) where an extra layer of transport is not used and devices connected directly to PCIe bus.

Starting with ONTAP 9.5, NVMe ANA protocol supported which provide, similarly to ALUA, multipathing functionality to NVMe. ANA for NVMe currently supported only with SUSE Enterprise Linux 15, VMware 6.7 and Windows Server 2012/2016. FC-NVMe without ANA supported with SUSE Enterprise Linux 12 SP3 and RedHat Enterprise Linux 7.6.

FC-NVMe

NVMeoF supported only on All-Flash FAS systems and not for Entry level A200 and A220 systems due to the lack of FC 32 Gb ports. Subsystem in NVMe used for the same purpose as iGroups, it allows initiator host NQN addresses which allowed to access a namespace. A namespace in this context is very similar to a LUN in FCP or iSCSI. Do not mix up namespace term in NVMe with a single namespace in ONTAP cluster.
Here is the hierarchy visualization & logical representation of FC-NVMe protocol in ONTAP cluster and corresponding commands (highlighted in grey):

Spirit of this article

This article explains principles, architecture, NetApp’s unique approaches and maybe even spirit of ONTAP clusterization. Each configuration, model and appliance have their nuances, which left out of the scope of this article. I’ve tried to give a general direction of the ideas behind NetApp innovative technologies, while (trying) not putting too many details to the equation to keep it simpler but not to lose important system architecture details. This is a far not complete story about ONTAP; for example, I didn’t mention about 7-Mode Transition Tool (7MTT) required for the transition to Clustered ONTAP to make complex information easier to consume nor didn’t go to WAFL detail explanation. Therefore some things might be a bit different in your case.

Summary

Clustered ONTAP first time was introduced around 2010 in version 8. After almost 10 years of hardening ONTAP (cluster) become mature, highly scalable and flexible solution with not just unique, unprecedented on the market functionalities in a single product but also impressive performance thanks to its WAFL versatility & clusterization capabilities.

Continue to read

How ONTAP Memory work

Zoning for cluster storage in pictures

Disclaimer

Please note in this article I described my own understanding of the internal organization of ONTAP systems. Therefore, this information might be either outdated, or I simply might be wrong in some aspects and details. I will greatly appreciate any of your contribution to make this article better, please leave any of your ideas and suggestions about this topic in the comments below.

All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.

How does the ONTAP cluster work? (part 3)

This article is part of the series How does the ONTAP cluster work? Also previous series of articles How ONTAP Memory work will be a good addition to this one.

Horizontal Scaling Clusterization

Horizontal scaling ONTAP clusterization came from Spinnaker acquisitions and often referred by NetApp as “Single Namespace,” “Horizontal Scaling Cluster,” or “ONTAP Storage System Cluster,” or “Scale-out cluster,” or just “ONTAP Cluster.” This type of clusterization often confused with HA pair or even with MetroCluster functionality. So to distinguish this one from others in ONTAP I will call it as the third type of clusterization. While MetroCluster and HA are Data Availability and even Data Protection technologies, single namespace clusterization does not provide data protection nor Data Availability: if there will be a hardware failure, the third type of clusterization is not involved in helping to mitigate such a problem. ONTAP forms (third type of) cluster out of one or a few HA pairs (multiple single-nodes are not supported in a single cluster) and adds to ONTAP system Non-Disruptive Operations (NDO) functionality such as non-disruptive online data migration across nodes in the cluster and non-disruptive hardware upgrade or online IP address migration. Data migration for NDO operations in ONTAP Cluster require dedicated Ethernet ports for such operations; they called cluster interconnect interfaces and does not use HA interconnect interfaces for this purpose. Cluster interconnect and HA interconnect interfaces couldn’t share the same ports, until A320 system.

Cluster interconnect with a single HA pair could have directly connected cluster interconnect ports (switch-less config) while systems with 4 or more nodes require two dedicated Ethernet cluster interconnect switches. ONTAP Cluster could consist only from an even number of nodes (they must be configured as HA pairs) except for Single-node cluster. Single-node cluster ONTAP system also called non-HA (or stand-alone), in such a configuration another cluster nodes cannot be added to a single node cluster, but single-node cluster can be converted to HA system and then other HA pairs can be added. ONTAP Cluster managed with a single pane of glass built-in management through Web-based GUI, CLI (SSH and PowerShell) and API. ONTAP Cluster provides Single Namespace for NDO operations through Storage Virtual Machines (SVM). Single Namespace in ONTAP system is a name for a collection of techniques used by (the third type) cluster to provide a level of abstraction and separate data from front-end network connectivity with data protocols like FC, FCoE, FC-NVMe, iSCSI, NFS and SMB from the data in volumes and therefore provide data virtualization. This virtualization provides online data mobility across cluster nodes while clients connected over data protocols still can access their data.

The general idea behind the single namespace is to trick clients so they would think they connected to a single device, while in reality connected to a cluster which consists of a bunch of nodes. This ”trick” work in different ways with different protocols. For example with FC protocol each node’s FC port gets unique WWPN address, while cluster SVM has a single WWNN, in this way client connected to the cluster consider it as a single FC node with multiple active ports, while some of them reported as optimized for traffic and some are none-optimized, in a very similar way it works with iSCSI and NVMeoF. With FC & iSCSI ALUA protocol used to switch between ports & links in case it becomes unavailable. With pNFS cluster operate in a similar to SAN protocol way: nodes in a cluster have interfaces with IP address, so clients perceive SVM as a single node with multiple active interfaces. ONTAP reports to clients ports as optimized which have direct access to nodes which serve volume with the data, and only if those ports not available, clients will use other active none-optimized ports. If protocols like NFS v3, NFS v4, SMB v2, and SMB v3 do not have such capabilities like SAN ALUA or pNFS, then ONTAP has another trick in its sleeve: Single Namespace provides several techniques for non-disruptive IP address migration for data protocols in case node or port dies.

SMB Continuous Availability (CA) extension to SMB v3 allows clients not to drop connections and this provides transparent failover in case a port, link or a node went down. Therefore MS SQL & Hyper-V servers on file share can survive. Without CA support in SMB protocol, in case of IP address migration to another port, clients will get session disruption, so only user file shares recommended to use. Since NFS v3 is a stateless protocol, if an IP address will migrate to another port or node, clients will not experience interruption. In the case of SAN, protocols interfaces do not migrate, but rather a new path selected.

Indirect data path

In some cases when data resides on one controller and this data accessed through another controller, then indirect data access occurs: For example hosts access network address through LIF 3A on node 3, while volume with data located on data_aggregate01 on node 1. In this scenario node 3 will access controller 1 through cluster interconnect interfaces & switches, get the data from node 1, and provide the information to the hosts requested it from LIF 3A interface which located on node 3 ports, and in some cases controller which owns data, in this example node 1, can reply directly to hosts. This functionality introduced as part of single namespace strategy (the third type of clusterization) to always provide hosts access to data no matter of location of the network addresses and volumes. Indirect data access occurs rarely in the cluster in situations like a LIF migrated by admin or cluster to another port; a volume migrated to another node; or if a node port went down. Though indirect data path adds some small latency to operations, in most of the cases it can be ignored. Some protocols like pNFS, SAN ALUA, NVMe ANA can automatically detect and switch its primary path to ports on the node with direct access to the data. Again, this (third) type of clusterization is not a data protection mechanism, but rather online data migration functionality.

Heterogeneous cluster

Cluster (the third type of clusterization) can consist of different HA pairs: AFF and FAS, different models and generations, performance and disks, and can include up to 24 nodes with NAS protocols or 12 nodes with SAN protocols. SDS systems can’t intermix with physical AFF or FAS appliances. The main purpose of the third type of customization is not data protection but rather non-disruptive operations like online volume migration or IP address migration between all the nodes in the cluster.

Storage Virtual Machine

Also known as Vserver or sometimes SVM. Storage Virtual Machine (SVM) is a layer of abstraction, and alongside with other functions, it virtualizes and separates physical front-end data network from data located on FlexVol volumes. Used for Non-Disruptive Operations and Multi-Tenancy. SVMs lives on nodes and on the image below pictured on disk shelves around volummes just to demonstrate each volume belong only to a single SVM.

Multi-Tenancy

ONTAP provides two techniques for Multi-Tenancy functionality: SVM and IP Spaces. On the one hand, SVMs are like KVM Virtual Machines; they provide virtualization abstraction from physical storage but on another hand quite different because unlike ordinary virtual machines does not allow to run third-party binary code like in Pure storage systems; they just provide a virtualized environment and storage resources instead. Also, SVMs, unlike ordinary virtual machines, does not run on a single node, SVM runs as a single entity on the whole cluster (unless it looks to system admin that way). SVM divide storage system into slices so few divisions or even organizations can share a storage system without knowing and interfering with each other while using same ports, data aggregates and nodes in the cluster and using separate FlexVol volumes and LUNs. Each SVM can run its own front end data protocols, a set of users, use its network addresses and management IP. With the use of IP Spaces users can have the same IP addresses and networks on the same storage system without interfering and network conflicts. Each ONTAP system must run at least one Data SVM to function but may run more. There are a few levels of ONTAP management: Cluster Admin level has all the privileges. Each Data SVM provides to its owner vsadmin user which have nearly full functionality like Cluster Admin level but lucks management of physical level like RAID group configuration, Aggregate configuration, physical network port configuration. Vsadmin can manage logical objects inside its SVM: create, delete and configure LUNs, FlexVol volumes and network interfaces/addresses so two SVMs in a cluster can’t interfere with each other. One SVM cannot create, delete, change or even see objects of another SVM so for SVM owners such an environment looks like they are only users on the entire storage system cluster. Multi-Tenancy is a free functionality in ONTAP. On the image below SVMs pictured on top of ONTAP cluster, but in reality, SVMs are part of ONTAP OS.

Non Disruptive Operations

There a few Non-Disruptive Operations (NDO) and Non-Disruptive Upgrade (NDU) with (Clustered) ONTAP system. NDO data operations include: data aggregate relocation within an HA pair between nodes, FlexVol volume online migration (known as Volume Move operation) across aggregates and nodes within the Cluster, LUN migration (known as LUN Move operation) between FlexVol volumes within the Cluster. LUN move and Volume Move operations use Cluster Interconnect interfaces for data transfer (HA-CI is not in use for such operations). SVM behave differently with network NDO operations, depending on the front-end data protocol. To decrease latency to its original level FlexVol volumes and LUNs should be located on the same node with network address through which the clients access the data, so network address could be created for SAN or moved for NAS protocols. NDO operations are free functionality.

NAS LIF

For NAS front-end data protocols there are NFSv2, NFSv3, NFSv4, CIFSv1, SMBv2, and SMB v3 protocols which do not provide network redundancy with the protocol itself, so they rely on storage and switch functionalities for this matter. ONTAP support Ethernet Port Channel and LACP with its Ethernet network ports on L2 layer (known in ONTAP as interface group or ifgrp), within a single node. And also ONTAP provides non-disruptive network failover between nodes in the cluster on L3 layer with migrating Logical Interfaces (LIFs) and associated IP addresses, similarly to VRRP, to the survived node and back home when failed node restored.

Though new versions of NAS protocols have built-in multipathing functionality: Extensions to NFS v4.1 protocol like pNFS (Supported starting with ONTAP 9.0) and NFS Session Trunking (NFS Multipathing. Not yet supported with ONTAP 9.6), and SMB v3 extension called SMB Multichannel (Available starting with ONTAP 9.4) allows automatically switch between paths in case of network link failure, while SMB Continuous Availability (CA) helps to preserve sessions without interruption. Unfortunately, all of these capabilities have limited support from clients. Until they become more popular ONTAP, will relay on build-in NAS LIF migration capabilities to move interfaces with assigned network addresses to survived node & port.

FailoverGroup

Failover group is functionality available only to NAS protocols and applied only to Ethernet ports/VLANs. SAN interfaces cannot (and do not need) to online migrate across cluster ports like NAS LIFs, therefore do not have failover group functionality. Failover group is a prescription to a LIF interface were to migrate in case if the hosted port will go down and should it return back automatically. By default FailoverGroup equal to Broadcast Domain. It is a good practice to specify manually between which ports a LIF can migrate, especially in the case where a few VLANs are used, so the LIF would not migrate to another VLAN. A failover group can be assigned to multiple LIFs, and each LIF can be assigned to a single failover group.

Broadcast Domain

A Broadcast Domain is a list of all the ethernet ports in the cluster which using the same MTU size and therefore used only for Ethernet ports. In many cases, it is a good idea to separate ports of different speeds. Unless of cause storage administrator wants to mix ports with lower speed & higher speed with the conjunction of a failover group to prescribe LIF migration from high-speed ports to slower speed ports in case if the first ports are unavailable, that is rarely the case and usually needed only with systems with a minimal number of ports. Each Ethernet port can be assigned only to one Broadcast Domain. If a port is a part of ifgroup, then such ifgroup port assigned to a Broadcast Domain. If a port or an ifgroup have VLANs, then Broadcast Domain assigned to each VLAN on that port or ifgroup.

SAN LIF

For front-end data SAN protocols. ALUA feature used for network load balancing and redundancy with FCP and iSCSI protocols, so all the ports on the node where data located are reported to clients as an active optimized (preferred), and if there are more than one port, ALUA will make sure hosts will load balance between them. And similarly it works with ANA in NVMe. While all other network ports on all other nodes in the cluster are reported by ONTAP to hosts as active none-optimized, so in case of one port or entire node goes down, the client will have access to its data using non-optimized path. Starting with ONTAP 8.3 Selective LUN Mapping (SLM) was introduced to reduce the number of unnecessary paths to the LUN and removes non-optimized paths to the LUN through all other cluster nodes except for HA partner of the node owning the LUN so cluster will report to the host paths only from the HA pair where LUN is located. Because ONTAP provides ALUA/ANA functionality for SAN protocols, SAN network LIFs do not migrate like with NAS protocols. When volume or LUN migration is finished, it is transparent to the storage system’s clients because of ONTAP Architecture and can cause temporary or permanent data indirect access through ONTAP Cluster interconnect (HA-CI is not in use for such situations) which will slightly increase latency for the clients. SAN LIFs used for FC, FCoE, iSCSI & FC-NVMe protocols.

iSCSI LIFs can live on the same ifgroup, port or VLAN with NAS LIFs since both using Ethernet ports.

On the image below pictured ONTAP cluster with 4 nodes (2 HA pairs) and a host accessing data over a SAN protocol.

Read more about Zoning for ONTAP clusters here.

VIP LIF

VIP (Virtual IP) LIFs, also known as BGP LIFs, require Top-of-the-Rack BGP Router to be used. VIP data LIFs used with ethernet for NAS environment. VIP LIFs, automatically load-balance traffic based on routing metrics and avoids inactive unused links and ports, unlike it usually happens with NAS protocols. VIP LIFs provides distribution across all the LIFs in the cluster, not limited to a single node as in NAS LIFs. VIP LIFs provides smarter load balance than it was realized with hash algorithms in Ethernet Port Channel & LACP with interface groups. VIP LIF interfaces are tested and can be used with MCC and SVM-DR and provide a more reliable, predictable and faster switch to the survived links & paths than NAS LIFs but require BGP routers.

Management interfaces

Node management LIF interface can migrate with associated IP address across Ethernet ports of a single node and available only while ONTAP running on the node. Usually, management interface placed on e0M port of the node; Node management IP sometimes used by cluster admin to communicate with a node to cluster shell in rare cases where commands have to be issued from a particular node. Cluster Management LIF interface with associated IP address available only while the entire cluster is up & running and by default can migrate across Ethernet ports, often located on one of the e0M ports on one of the cluster nodes and used by the cluster administrator for storage management. Management interfaces used for API communications, HTML GUI & SSH console management, by default SSH, connect administrator with cluster shell. Service Processor (SP) or BMC interfaces available only at hardware appliances like FAS & AFF, and each system has only SP or BMC. SP/BMC allows SSH out-of-band console communications with an embedded small computer installed on controller main-board and similarly to IPMI, or IP KVM enables to connect, monitor & manage controller even if it does not boot ONTAP OS. With SP/BMC it is possible to forcibly reboot or halt a controller and monitor coolers, temperature, etc.; once connected to SP/BMC console by SSH administrator can switch to cluster shell through it with issuing system console command; each controller has one SP/BMC interface which does not migrate like some other management interfaces. Usually, e0M and SP both lives on single management (wrench) physical Ethernet port but each have its own dedicated MAC address. Node LIFs, Cluster LIF & SP/BMC often using the same IP subnet. SVM management LIF, similarly to cluster management LIF, it can migrate across all the Ethernet ports on the nodes of the cluster and dedicated for a single SVM management. SVM LIF does not have GUI capability and can facilitate only for API Communications & SSH console management; SVM management LIF can live on e0M port but often placed by administrators on a data port in the cluster and usually on a dedicated management VLAN and can be different from IP subnets of node & cluster LIFs.

Cluster interfaces

Each cluster interconnect LIF interface usually lives on dedicated Ethernet port and cannot share ports with management and data interfaces. Cluster interconnect interfaces used for horizontal scaling functionality at times when, for example, a LUN or a Volume migrates from one node of the cluster to another node; cluster interconnect LIF similarly to node management LIFs can migrate only between ports of a single node. A few cluster interconnect interfaces can coexist on a single port, but usually, this happens temporarily because of cluster port recabling. Inter-cluster interface LIFs on another hand can live and share the same Ethernet ports with data LIFs and used for SnapMirror replication; Inter-cluster interface LIFs, similarly to node management & cluster interconnect LIFs can only migrate between ports of a single node.

Continue to read

How ONTAP Memory work

Zoning for ONTAP Cluster

Disclaimer

Please note in this article I described my own understanding of the internal organization of ONTAP systems. Therefore, this information might be either outdated, or I simply might be wrong in some aspects and details. I will greatly appreciate any of your contribution to make this article better, please leave any of your ideas and suggestions about this topic in the comments below.

All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.

How does the ONTAP cluster work? (part 2)

This article is part of the series How does the ONTAP cluster work? Also previous series of articles How ONTAP Memory work will be a good addition to this one.

High Availability

I will call HA the first type of clusterization and its main purpose is data availability. Even though a single HA pair consists of two nodes (or controllers), NetApp has designed it in such a way it appears as a single storage system from clients perspective of view. HA configurations in ONTAP use several techniques to present the two nodes of the pair as a single system. This allows the storage system to provide its clients with nearly uninterrupted access to their data should a node fail unexpectedly.

For example: on the network level, ONTAP will temporarily migrate the IP address of the failed node to the surviving node, and where applicable it will also temporarily switch ownership of disk drives from the downed node to the surviving node. On the data level, the contents of the disks that are assigned to the downed node will automatically be available for use via the surviving node.

An aggregate can include only disks owned by a single node; therefore, each aggregate owned by a node and an upper objects such as FlexVol volumes, LUNs, File Shares served within a single controller (until FlexGroup). Since each node in HA pair can have its own disks and aggregates and serve them independently; therefore, such configurations are called Active/Active where both nodes are utilized simultaneously even though they are not serving the same data. In case one node fails, another will take over and serve its partner’s and its own disks, aggregates, and FlexVol volumes. HA configurations were only one controller has data aggregates, called Active/Passive, were passive node has only root aggregate and simply waiting to take over in case active will fail.

Once the downed node of the HA pair has been booted, up and running, a “giveback” command issued by defaul, to return disks, aggregates and FlexVol resources back to the original node.

Share nothing architecture

There are storage architectures each node serves the same data with symmetrical client access; ONTAP is not one of them. Only one node serves each disk/aggregate/FlexVol at a time, and if that node fails, another takes over in ONTAP. ONTAP using architecture known as share nothing, meaning no special equipment really needed to such architecture. Even though in hardware appliances we can see ”special” devices like NVRAM/NVDIMM, and disks with dual ports, each node in an HA pair runs its own instance of ONTAP on two separate controllers were only NVLogs shared over HI-CI Ethernet connections between HA partners. Though ONTAP is using these special devices in its hardware appliances, SDS version of ONTAP can work without them perfectly well: NVLogs are still replicated between HA partners, and instead of having two data ports and access the same disk drives with two controllers, ONTAP SDS can simply replicate data and keep two copies of data, like in MCC configurations. Share nothing architectures are particularly useful in scale-out clusters: you can add controllers with different models, configurations, disks, and even with slightly different version of OS if needed.

On the contrary, storage systems with symmetrical data access often build on monolithic architectures, which in turn suitable only to SAN protocols. While symmetrical access and monolithic architecture might sound ”cool” and seem to give more performance from the first sight, on practice share nothing architectures shoved no less performance. Also, the monolithic architectures showed plenty of inflexibility and disadvantages. For example, when the industry moved to flash media turns out disks are no longer a performance bottleneck, but controllers and CPUs are. Which means you need to add more nodes to your storage system to increase performance. This problem can be solved with scale-out clusters but monolithic architectures particularly very bad on that front. Let me explain why.

First of all, if you have a monolithic architecture with symmetric data access, each controller needs to have access to each disk, and when you are adding new controllers you need to rearrange disk shelves connections to facilitate that need, second, all the controllers in such a cluster have to be the same model with the same firmware, these clusters become very hard to maintain and add new nodes, plus such architectures usually very limited with maximum number of controllers you can add to such a cluster. Another example, closer to practice then to theory: imagine after a 3 years you need to add new node to your cluster to increase performance, while on the market there most probably available more powerful controllers with the same price you’ve bought your old controllers, but you can add only old controllers to the cluster.

Due to its monolithic nature, it becomes a very complex architecture to scale, most vendors of cause trying to hide this underlying complexity from its customers to simplify the usage of such systems, and some A-Brand systems are excellent on that front. But still, monolithic inflexibility makes such systems complex on low-level and thus very expensive, because it requires specially designed hardware, main boards, and special buses. While on another hand, share nothing architectures, needs no modifications for commodity servers to be used as storage controllers and hardware storage appliances, while no scalability nor performance is the problem for them.

HA interconnect

High-availability clusters (HA clusters) is the first type of clusterization introduced in ONTAP systems (that’s why I call it the first). The first, the second and the third type of ONTAP clusterization are not official or well-known industry terms, – I’m using them only to differentiate ONTAP capabilities while keeping them under the same umbrella because on some level they all are clusterization technologies. HA aimed to ensure an agreed level of operations. People often confuse HA with the horizontal scaling ONTAP clusterization that came from the Spinnaker acquisition; therefore, NetApp, in its documentation for Clustered ONTAP systems, refers to an HA configuration as an HA pair rather than as an HA cluster. I will reference to horizontal scaling ONTAP (Spinnaker) clusterization as the third type of clusterization to make it even more difficult. I am just kidding, with doing so I’m drawing parallels with all three types of customization so you will easily find differences between them.

An HA pair uses network connectivity between the pairs called a High Availability interconnect (HA-IC). The HA interconnect can use Ethernet ( in some older systems you might find InfiniBand) as the communication medium. The HA interconnect used for non-volatile memory log (NVLogs) replication between two nodes in an HA pair configuration using RDMA technology to ensure an agreed level of operations during events like unexpected reboots. Usually, ONTAP assigns dedicated, non-sharable HA ports for HA interconnect which could be external or built-in to storage chassis (and not visible from the outside). We should not confuse the HA-IC with the inter-cluster or intra-cluster interconnects that are used for SnapMirror. Inter-cluster and intra-cluster interfaces can coexist with interfaces used for data protocols on data ports. Also, HA-CI traffic should not be confused with Cluster Interconnect traffic used for horizontal scaling & online data migration across the multi-node cluster, and usually these two interfaces live on two different ports. HA-IC interfaces are visible only on the node shell level. Starting with A320 HA-IC and Cluster interconnect traffic to use the same ports.

MetroCluster

MetroCluster is a free functionality for ONTAP systems for metro high availability with synchronous replication between two sites; this configuration might require some additional equipment. There can be only two sites. To distinguish between “old” MetroCluster in 7-Mode and “new” MetroCluster in Cluster-Mode, last one shortened as MCC. I will call MCC as the second type of ONTAP clusterization. The primary purpose of MCC clusterization is to provide data protection and data availability across two geographical locations and switch clients from one site to another in case of a disaster to continue access to the data.

MetroCluster (MCC) is an additional level of data availability to HA configurations and supported initially only with FAS and AFF storage systems, later SDS version of MetroCluster was introduced with ONTAP Select & Cloud Volumes ONTAP products. An MCC configuration consists of two sites (each site can have a single node or HA pair), both form MetroCluster. The distance between sites can reach up to 300 km (186 miles) or even 700 km (436 miles), therefore, called geo-distributed system. Plex and SyncMirror are the critical underlying technologies for MetroCluster which synchronize data between two sites. In MCC configurations NVLogs are also replicated among storage systems between sites in this article I will refer this traffic as metrocluster traffic, to distinguish it from HA interconnect, and Cluster interconnect traffic.

MetroCluster uses RAID SyncMirror (RSM) and plex technique where on one site number of disks form one or more RAID groups aggregated in a plex, while the second site have the same amount of disks with the same type and RAID configuration aggregated into the second plex where one plex replicate data to another. Alongside with NVLogs ONTAP replicates Configuration Replication Service (CRS) metadata. NVLogs are replicated from one system to another as part of SyncMirror process and then on destination system NVLogs restored to MBUF and dumped to disks as part of next CP process, while from the logical perspective of view it looks like data synchronously replicated between two plexes groups. To simplify things, NetApp usually shows that one plex synchronously replicates to another, but in reality, NVLogs synchronously replicated between non-volatile memories of two sites. Two plexes form an aggregate and in case of a disaster on one site, the second site provides read-write access to the data. MetroCluster Support FlexArray technology and ONTAP SDS.

As part of the third type of clusterization, individual data volumes, LUNs and LIFs could online migrate across storage nodes in the MetroCuster only within a single site where data originated from: it is not possible to migrate individual volumes, LUNs or LIFs using cluster capabilities across sites unless MetroCluster switchover operation (the second type of clusterization) is used to switch entire half of the cluster with all the data, volumes, LIFs and storage configuration from one, so clients and applications access to all the data from another location.

With MCC it is possible to have one or more storage nodes per site, so one node per site known as 2-node configuration (or two-pack configuration), 2-node per site known as 4-node configuration and 8-node configuration with 4-nodes per site. Local HA partner (if exists) and remote partner must be the same model: in 2 or 4-node configurations, all nodes must be the same model & configuration. In MCC configuration each one remote and one local storage node form a Disaster Recovery Pare (DR Pare) across two sites while two local nodes (if there is partner) form local HA pair, thus each node synchronously replicates data in non-volatile memory two nodes: one remote and one local (if there is one). In other words, the 4-node configuration consists of two HA pares and in this case NVLogs replicated to a remote site and local HA partner as in normal non-MCC HA system, while 2-node configuration NVLogs replicated only to its remote partner.

MCC with one node on each site called two-pack (or 2-node) MCC configuration.

8-Node MCC

8-node MCC configuration consists of two almost independent 4-node MCC (each 4-node with two HA pair), as in 4-node configuration, each storage node have only one remote partner and only one local HA partner. The only difference between two completely independent 4-node MCC and 8-node configuration MetroCluster is that 8-node share cluster interconnect switches therefore entire 8-node cluster seen by clients as a single namespace system administrator can move data online between all the nodes in MetroCluster within a local site. Example of 8-node MCC is four nodes of AFF A700 and four nodes of FAS8200, where two nodes of A700 and two nodes of FAS8200 on one site and the second half on the another site.

MCC network transport: FC & IP

MCC can use two network transports for synchronization: FC or IP. Most FC configurations require dedicated FC-VI ports usually located on an FC-VI card but some FAS/AFF models can convert on-board FC ports to FC-VI mode. IP requires iWRAP interfaces which can live on ethernet ports (25 GbE or higher), which usually available on an iWRAP card. Some models like Entry-level A220 can use onboard ports and share ports with cluster interconnect traffic, while MCC-FC do not support Entry systems.

MCC: Fabric & Stretched

Fabric configurations are configurations with switches, while stretched configurations are configs without a switch. Both Fabric & Stretched terms usually applies only to FC network transport because IP transport always require a switch. Stretched configs can use only 2-nodes in a MetroCluster. With MCC FC stretched configs it is possible to build 2-node cluster stretched up to 300 meters (984 feet) without a switch, such configurations require special optical cables with multiple fibers in it, because of necessity to cross-connect all controllers and all disk shelves. To reduce the number of fibers stretched configurations can use FC-SAS bridges used to connect disk shelves to it, then cross-connect controllers and the FC-SAS bridges and the second option to reduce the number of required fiber links is to use FlexArray technology instead of NetApp disk shelves.

Fabric MCC-FC

FAS and AFF systems with ONTAP software versions 9.2 and older utilize FC-VI ports and for long distances require dedicated only for MetroCuster four Fibre Channel switches (2 on each site) and 2 FC-SAS bridges per each disk shelf stack, thus minimum 4 total for 2 sites and minimum 2 dark fiber ISL links with optional DWDMs for long distances. Fabric MCC require FC-SAS bridges. 4-node and 8-node configurations require a pair of cluster interconnect switches.

MCC-IP

Starting with ONTAP 9.3 MetroCluster over IP (MCC-IP) was introduced with no need for a dedicated back-end Fibre Channel switches, no FC-SAS bridges and no dedicated dark fiber ISL which previously were needed for MCC-FC configurations. In such configuration disk shelves directly connected to controllers and cluster switches used for MetroCluster (iWRAP) and Cluster interconnect traffic. Initially, only A700 & FAS9000 systems supported MCC-IP. MCC-IP available only in 4-node configurations: 2-node Highly Available system on each site with two sites total. With ONTAP 9.4, MCC-IP supports A800 system and Advanced Drive Partitioning in the form of Rood-Data-Data (RD2) partitioning for AFF systems, also known as ADPv2. ADPv2 supported only on all-flash systems. MCC-IP configurations support single disk shelf per site where SSD drives partitioned in ADPv2. MetroCluster over IP requires Ethernet cluster switches with installed ISL SFP modules to connect with the remote location and utilize iWRAP cards in each storage controller for synchronous replication. Starting with ONTAP 9.5 MCC-IP supports distance up to 700 km and SVM-DR feature, AFF A300, and FAS8200 systems. Beginning with ONTAP 9.6 MCC-IP supports Entry-level systems A220 and FAS2750, also in these systems MCC (iWRAP), HA, and Cluster interconnect interfaces lives on the cluster interconnect onboard ports, while mid-range and high-end systems still require a dedicated iWRAP card.

Plex

Similar to RAID-1, plexes in ONTAP systems can keep mirrored data in two places, but while conventional RAID-1 must exist within the bounds of one storage system, two plexes could be distributed between two storage systems. Each aggregate consists of one or two plexes. Ordinary HA or single-node storage systems have only one plex for each aggregate while SyncMirror local or MetroCluster configurations have two plexes for each aggregate. Each plex includes underlying storage space from one or more NetApp RAID groups or LUNs from third-party storage systems (see FlexArray) in a single plex similarly to RAID-0. If an aggregate consists of two plexes, one plex is considered a master and the second as a slave; slaves must consist of the same RAID configuration and drives. For example, if we have an aggregate consisting of two plexes where the master plex consists out of 21 data and three parity 1.8 TB SAS 10k drives in RAID-TEC, then slave plex must consist of 21 data and 3 parity 1.8 TB SAS 10k drives in RAID-TEC. Second example with hybrid aggregates, if we have an aggregate consisted from two plexes where master plex consists of one RAID 17 data and 3 parity SAS drives 1.8 TB SAS 10k configured as RAID-TEC and second RAID in the master plex is RAID-DP with 2 data and 2 parity SSD 960 GB, then the second plex must have the same configuration: one RAID 17 data and 3 parity SAS 10k drives 1.8 TB configured as RAID-TEC and the second RAID in the slave plex in RAID-DP with 2 data and 2 parity SSD 960 GB. MetroCluster configurations use SyncMirror technology for synchronous data replication.

There are two SyncMirror options: MetroCluster and Local SyncMirror; both using the same plex technique for synchronous replication of data between two plexes. Local SyncMirror creates both plexes in a single controller and is often used for additional security to prevent failure for an entire disk shelf in a storage system. MetroCluster allows data to be replicated between two storage systems.

MetroCluster SDS

Is a feature of ONTAP Select software, similarly to MetroCluster on FAS/AFF systems MetroCluster SDS (MC SDS) allows to synchronously replicate data between two sites using Plex & SyncMirror and automatically switch to survived node transparently to its users and applications. MetroCluster SDS work as ordinary HA pair so data volumes, LUNs and LIFs could be moved online between aggregates and controllers on both sites, which is different from traditional MetroCluster on FAS/AFF systems where data cloud be moved across storage cluster nodes only within the site where data located initially. In traditional MetroCluster the only way for applications to access data locally on the remote site is to disable one entire site, this process called switchover wherein MC SDS the HA process occurs. MCC supports 2,4 and even 8-node configurations, while MC SDS sports only 2-node configuration. MetroCluster SDS uses ONTAP Deploy as the mediator (in FAS and AFF world this built-in software known as MetroCluster tiebreaker) which came with ONTAP Select as a bundle and generally used for deploying clusters, installing and
monitoring licenses.

Continue to read

How ONTAP Memory work

Zoning for ONTAP Cluster

Disclaimer

Please note in this article I described my own understanding of the internal organization of ONTAP systems. Therefore, this information might be either outdated, or I simply might be wrong in some aspects and details. I will greatly appreciate any of your contribution to make this article better, please leave any of your ideas and suggestions about this topic in the comments below.

All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.

How does the ONTAP cluster work? (part 1)

In my previous series of articles I explained how ONTAP system memory works and talked about:
NVRAM/NVMEM, NVLOGs, Memory Buffer, HA & HA interconnects, Consistency Points, WAFL iNodes, MetroCluster data availability, Mailbox disks, Takeover, Active/Active and Active/Passive configurations, Write-Through, Write Allocation, Volume Affinities (Wafinity), FlexGroup, RAID & WAFL interaction, Tetris and IO redirection, Read Cache, NVRAM size, role of the system battery and boot flash drive, Flash media and WAFL compatibility. Those articles going be a good addition & help to understand this one, so go & check them too.

First I need to tell that clusterization is a very broad term, and in many vendors and technologies, it has a different meaning. ONTAP uses three different types of clusterization and one of the primary purpose of this article to explain each and how they are a different one from another and how they can complement each other and what additional benefits ONTAP can get out of them. Before we go to clusterization, we need to go deeper and explore other ONTAP components to understand how it works.

When someone is speaking about ONTAP cluster, they most probably mean horizontal scaling clusterization used to scale-out storage (the third type of clusterization).

Storage

There are a few platforms ONTAP support: FAS appliance, AFF appliance, and SDS virtual appliance. NetApp FAS storage systems which contain only SSD drives with installed SSD-optimized ONTAP OS called All-Flash FAS (AFF). There is also a Lenovo DM line of products which using ONTAP. NetApp HW appliances are using either SATA, Fibre Channel, SAS, SSD disk drives or LUNs from 3rd party storage arrays, which it groups into RAID groups and then into Aggregates to combine disk performance and capacity into a single pool of storage resources. SDS appliances can use space from the hypervisor as virtual disks and join space into aggregates or can use physical disk drives passed through to ONTAP and build RAID out of them and then aggregates.

FlexVol

FlexVol volume is a logical space that placed on top of an aggregate, each volume can expand or shrink in size plus we can apply and change performance limits to each volume. A FlexVol helps to separate performance & capacity from an aggregate pool of resources and flexibly distribute them as needed. Some volumes need to be big but slow, and some very fast but small; volumes can be re-sized and performance re-balanced, – FlexVol is the technology which achieve this goal in ONTAP architecture. Clients are accessing storage from FlexVol volumes over SAN & NAS protocols. Each volume exists on a single aggregate and served by a single storage node (controller).

If two FlexVol volumes created, each on two aggregates and those aggregates owned by two different controllers, and system admin needs to use space from these volumes through a NAS protocol, then admin will create two file shares, one on each volume. In this case, admin most probably even will create different IP addresses; each will be used to access a dedicated file share. Each volume will have single write waffinity and there will be two buckets of space. Though even if two volumes reside on a single controller, and for example on a single aggregate (thus if the second aggregate exists, it will not be used in this case) and both volumes will be accessed through a single IP address, still there will be two write affinities, one on each volume and there still will be two separate buckets of space. So the more volumes you have, the more write waffinities you’ll have (better parallelization and thus more even CPU utilization, which is good), but then you’ll have multiple volumes (and multiple buckets for space thus multiple file shares).

FlexGroup

FlexGroup is a free feature introduced in version 9, which uses the clustered architecture of the ONTAP operating system. FlexGroup provides cluster-wide scalable NAS access with NFS and CIFS protocols. A FlexGroup creates multiple write affinities but on another hand, unlike FlexVol, combines space and performance from all the volumes underneath (thus from multiple aggregates and nodes). A FlexGroup Volume is a collection of constituent FlexVol volumes distributed across nodes in the cluster called “Constituents,” which are transparently joined in a single space. FlexGroup volume combines performance and capacity from all the constituent volumes and thus from all nodes of the cluster where they located. For the end user, each FlexGroup Volume is represented by a single, ordinary file-share with single space equal to the summary of space from all the constituent volumes (not visible to clients) and multiple reads & write waffinities.

NetApp will reveal the full potential of FlexGroup with technologies like NFS multipathing, SMB multichannel, pNFS, SMB CA, and VIP.

Technology NameFlexVolFlexGroup
1. NFS multipathing (session trunking)NoNo
2. SMB multichannelNoNo
3. pNFSYesNo
4. VIP (BGP)YesYes
5. SMB Continuous Availability (SMB CA)YesYes*

*Added in ONTAP 9.6

The FlexGroup feature in ONTAP 9 allows to massively scale in a single namespace to over 20 PB with over 400 billion files, while evenly spreading the performance across the cluster. Starting with ONTAP 9.5 FabricPool supported with FlexGroup, in this case, it is recommended to have all the constituent volumes to back up to a single S3 object storage bucket. FlexGroup supports SMB features for native file auditing, FPolicy, Storage Level Access Guard (SLA), copy offload (ODX) and inherited watches of changes notifications; Quotas and Qtree. SMB Contiguous Availability (CA) supported with FlexGroup in ONTAP 9.6 allows running MS SQL & Hyper-V. FlexGroup also supported on MetroCluster.

Clustered ONTAP

Today’s OS for NetApp AFF, FAS, Lenovo DM line and cloud appliances are known just as ONTAP 9, but before version 9 there was Clustered ONTAP (or Cluster-Mode, Clustered Data ONTAP or cDOT) and 7-mode ONTAP. 7-mode is the old firmware which had capabilities of the first and the second type of clusterization (High Availability and MetroCluster), while Clustered ONTAP 9 has all three HA, MCC, plus horizontal scaling clusterization). The reason why two existed for in parallel was Clustered ONTAP 8 didn’t have all reach functionality from 7-mode, so for a while, it was possible to run both modes (one at a time) on the same NetApp hardware. NetApp spent some time to bring all the functionality to Cluster-Mode, once finished the transition, 7-Mode was deprecated and with that milestone Clustered ONTAP updated to the next version and become ”just” ONTAP 9. ONTAP 8.2.4 was the last version of 7-Mode. Both 7-Mode & Cluster-Mode share a lot of similarities, for example, WAFL file system was used on both, but most were not compatible one with another, in previous example WAFL versions and functionality were different and thus incompatible, only limited compatibility was introduced mostly for migration purposes from 7-mode to Cluster-Mode. The last version of 7-Mide ONTAP 8.2.4 contains WAFL compatible with Cluster-Mode, to introduce fast but offline in-place upgrade to the newest versions of ONTAP.

In version 9, nearly all the features from 7-mode were successfully implemented in ONTAP (Clustered) including SnapLock, FlexCache, MetroCuster, SnapMirror Synchronous, while many new features that not available in 7-Mode were introduced, including features such as FlexGroup, FabricPool, and new capabilities such as fast-provisioning workloads and Flash optimization, NDAS, data compaction, AFF or many others. The uniqueness of NetApp’s Clustered ONTAP is in the ability to add heterogeneous systems (where all systems in a single cluster do not have to be of the same model or generation) to a single (third type) cluster. This provides a single pane of glass for managing all the nodes in a cluster, and non-disruptive operations such as adding new models to a cluster, removing old nodes, online migration of volumes, and LUNs while data is continuously available to its clients.

A node and controller (head or physical appliance) are very similar terms and often used interchangeably. The difference between them is that controller is a physical server with CPU, main board, Memory and NVRAM, while node is an instance of ONTAP OS running on top of controller. A node can migrate, for example when a controller replaced with a new one. ONTAP (the third type) Cluster consist of nodes.

FAS appliances

Are NetApp custom build & OEM hardware. Controllers in FAS systems are computers which running ONTAP OS. FAS systems are used with HDD and SSD drives. SSD often used for caching, but can be used in all-SSD aggregates as well. FAS systems can use NetApp disk shelves to add capacity to the storage or a 3rd party arrays. Each disk shelf connected to one storage system which consists out of one or two controllers (HA pair).

AFF appliances

All-Flash FAS appliance also known as AFF. Usually, NetApp All-Flash systems based on the same hardware as FAS but first one’s OS ONTAP optimized and works only with SSD media on the back end while FAS appliance can use HDD and SSD and SSD as cache. Hare are pairs of appliances which using the same hardware: AFF A700 & FAS9000, A300 & FAS8200, A200 & FAS2600, A220 & FAS2700, but AFF systems do not include FlashCache cards since there is no sense in caching operation from flash media on the flash media. Also, AFF systems do not support FlexArray third-party storage array virtualization functionality. Both AFF & FAS using the same firmware image and nearly all noticeable functionality for the end user are the same for both. However internally data processed and handled differently in ONTAP on AFF systems, for example, used different Write Allocation algorithms than on FAS systems. Because AFF systems have faster underlying SSD drives Inline data deduplication in ONTAP systems nearly not noticeable (no more than 2% performance impact on low-end systems).

Disks

FAS and AFF systems are using enterprise level HDD, and SSD (i.e., NVMe SSD) physical drives with two ports, each port connected to each controller in an HA pair. HDD and SSD drives can only be bought from NetApp and installed in NetApp’s Disk Shelves for FAS/AFF platform. Physical HDD and SSD drives, partitions on disk drives, and even LUNs imported from third-party arrays with FlexArray functionality are considered in ONTAP as a Disk. In SDS systems like ONTAP Select & ONTAP Cloud, logical block storage like virtual disk or RDM inside ONTAP also considered as a Disk. Do not confuse the general term “disk drive” and “disk drive term used in ONTAP system” because with ONTAP it could be entire physical HDD or SSD drive, a LUN or a partition on a physical HDD or SSD drive. A LUN imported from third-party arrays with FlexArray functionality in HA pair configuration must be accessible from both nodes of the HA pair as HDD or SSD drive. Each ONTAP disk has ownership on it to show which controller owns and serve the disk. An Aggregates can include only disks owned by a single node, therefore each aggregate owned by a node and any objects on top of it, as FlexVol volumes, LUNs, File Shares are served within a single controller. Each node have its own disks and aggregates and serve them. Where both nodes can be utilized simultaneously even though they not serving the same data.

ADP

Advanced Drive Partitioning (ADP) can be used in AFF & FAS systems depending on the platform and use-case. FlexArray technology does not support ADP. This technique mainly used to overcome some architectural requirements and reduce the number of disk drives in a NetApp FAS & AFF storage systems. There are three types of ADP:

  • Root-Data partitioning
  • Root-Data-Data partitioning (RD2 also known as ADPv2)
  • and Storage Pool.

Root-Data partitioning used in FAS & AFF systems to create small root partitions on drives to use them to create system root aggregates and therefore not to spend entire two physical disk drives for that purpose while the bigger portion of the disk drive will be used for data aggregate. Root-Data-Data partitioning is used in All-Flash systems only, it used for the same reason as Root-Data partitioning with the only difference that bigger portion of the drive left after root partitioning divided equally by two partitions, each partition assigned to one of the two nodes, therefore reducing the minimum number of drives required for an All-Flash system and reducing waste for expensive SSD space. Storage Pool partitioning technology used in FAS systems to equally divide each SSD drive by four pieces which later can be used for (only) FlashPool cache acceleration, with Storage Pool only a few SSD drives can be divided by up to 4 data aggregates which will benefit from FlashPool caching technology reducing minimally required SSD drives for FlashPool.

NetApp RAID in ONTAP

In NetApp ONTAP systems, RAID and WAFL are tightly integrated. There are several RAID types available within NetApp FAS and AFF systems:

  • RAID-4 with 1 dedicated parity disk allowing any 1 drive to fail in a RAID group.
  • RAID-DP with 2 dedicated parity disks allowing any 2 drives to fail simultaneously in a RAID group.
  • RAID-TEC US patent 7640484 with 3 dedicated parity drives, allows any 3 drives to fail simultaneously in a RAID group.

RAID-DP’s double parity leads to a disk loss resiliency similar to that of RAID-6. NetApp overcomes the write performance penalty of traditional RAID-4 style dedicated parity disks via WAFL and innovative use of its nonvolatile memory (NVRAM) within each storage system. Each aggregate consists of one or two plexes, and a plex consists of one or more RAID groups. Typical NetApp FAS or AFF storage system have only one plex in each aggregate, two plexes used in local SyncMirror or MetroCluster configurations. Therefore in systems without MetroCluster or local SyncMirror engineers might say “aggregates consist of RAID groups” to simplify things a bit because plex does not play a vital role in such configurations, while in reality an aggregate always have one or two plex and a plex consists of one or more RAID groups (see the picture with aggregate diagram). Each RAID group usually consists of disk drives of the same type, speed, geometry, and capacity. Though NetApp Support could allow a user to install a drive to a RAID group with same or bigger size and different type, speed and geometry for a temporary basis. RAID can be used with partitions too. Any data aggregates if containing more than one RAID group must have same RAID groups across the aggregate, same RAID group size is recommended, but NetApp allows to have an exception in the last RAID group and configure it as small as half of the RAID group size across aggregate. For example, such an aggregate might consist of 3 RAID groups: RG0:16+2, RG1:16+2, RG2:7+2. Within aggregates, ONTAP sets up flexible volumes (FlexVol) to store data that users can access. The reason ONTAP has ”default” RAID group size and that number is smaller than max RAID group size is to allow admin in the future to add only a few disk drives to existing RAID groups instead of adding a new RAID group with the full set of drives

Aggregates enabled as FlashPool consists of both HDD and SSD drives called hybrid aggregates and used in FAS systems. In FlashPool aggregates the same rules applied to the hybrid aggregate as to ordinary aggregates but separately to HDD and SSD drives, thus it is allowed to have two different RAID types: one RAID type for all HDD drives and one RAID type for all SSD drives in a single hybrid aggregate. For example SAS HDD with RAID-TEC (RG0:18+3, RG1:18+3) and SSD with RAID-DP (RG3:6+2). NetApp storage systems running ONTAP combine underlying RAID groups similarly to RAID-0 in plexes and aggregates, while in Hybrid aggregates SSD portion used for cache and therefore capacity from flash media not contributing to overall aggregate space. Also in NetApp FAS systems with FlexArray feature third party LUNs could be combined in a plex/aggregate similarly as in RAID-0. NetApp storage systems running ONTAP can be deployed in MetroCluster and local SyncMirror configurations which are using technique comparably to RAID-1 with mirroring data between two plexes in an aggregate.

Note that ADPv2 does not support RAID-4. RAID-TEC is recommended if the size of the disks used in an aggregate is greater than 4 TiB. RAID type in storage pool cannot be changed. RAID minimums for root aggregate (with force-small-aggregate true) are:

  • RAID-4 is 2 drives (1d + 1p)
  • RAID-DP is 3 drives (1d + 2p)
  • RAID-TEC is 5 drives (2d + 3p)

Aggregates

One or multiple RAID groups form an “aggregate,” and within aggregates ONTAP operating system sets up “flexible volumes” (FlexVol) to store data that hosts can access.

Similarly, to RAID-0, each aggregate merges space from underlying protected RAID groups to provide one logical piece of storage for flexible volumes therefore Aggregate does not provide data protection mechanisms but rather another layer of abstraction. Alongside with aggregates consisted out of disks and RAID groups, other aggregates could consist of LUNs already protected with third-party storage systems and connected to ONTAP with FlexArray, and in similar way it works in ONTAP Select or Cloud Volumes ONTAP. Each aggregate could consist of either LUNs or NetApp RAID groups. Flexible volumes offer the advantage that many of them can be created on a single aggregate and resized at any time. Smaller volumes can then share all the space & disk performance available to the underlying aggregate, and QoS allows to change the performance of flexible volumes on the fly. Aggregates can only be expanded, never downsized. Current maximum physical useful space size in an aggregate is 800 TiB for All-Flash FAS Systems. the limit applies on space in the aggregate rather then number of disk drives and may be different on AFF & FAS systems.

FlashPool

NetApp FlashPool is a feature on hybrid NetApp FAS systems which allows creating a hybrid aggregate with HDD drives and SSD drives in a single data aggregate. Both HDD and SSD drives form separate RAID groups. Since SSD also used for write operations, it requires RAID redundancy contrary to FlashCache which accelerate only read operations. In hybrid aggregate the system allows to use different RAID types for HDD and SSD, for example, it is possible to have 20 HDD 8TB in RAID-TEC while 4 SSD in RAID-DP or even RAID-4 with 960GB in a single aggregate. SSD RAID used as cache and improved performance for read-write operations for FlexVol volumes on the aggregate where SSD added as the cache. FlashPool cache similarly to FlashCache have policies for reading operations but also include write operations, and system administrator could apply those policies for each FlexVol volume located on the hybrid aggregate, therefore could be disabled on some volumes while others could benefit from SSD cache. Both FlashCache & FlashPool can be used simultaneously to cache data from a single FlexVol. To enable an aggregate with FlashPool technology minimum 4 SSD disks required (2 data, 1 parity, and 1 hot spare), it is also possible to use ADP technology to partition SSD into 4 pieces (Storage Pool) and distribute those pieces between two controllers so each controller’s aggregates could benefit from SSD cache when there is a small amount of SSD. FlashPool is not available with FlexArray and is available only with NetApp FAS native disk drives in NetApp’s disk shelves.

FabricPool

FabricPool technology available for all-SSD aggregates in FAS/AFF systems or in Cloud Volumes ONTAP on SSD media. Starting with ONTAP 9.4 FabricPool supported on ONTAP Select platform. Cloud Volumes ONTAP also supports HDD + S3 FabricPool configuration. FabricPool provides automatic storage tiering capability for cold data blocks from fast media (hot tier) on ONTAP storage to cold media to an S3 object storage (cold tier) and back. Each FlexVol volumes on a FabricPool-enabled all-SSD aggregates can have one out of four policies:

  • None – Does not tier data from a volume
  • Snapshot – Migrate cold data blocks captured in snapshots
  • Auto – Migrates cold data blocks from an active file system and snapshots to cold tier
  • All – this policy tiers all the data writing through directly to S3 object storage, metadata though always stays on SSD hot tier.

FabricPool preserves offline deduplication & offline compression savings. FabricPool tier-off blocks from active file system (by default 31-day data not been accessed) & support data compaction savings. Trigger for tiering from hot tier can be adjusted. The recommended ratio is 1:10 for inodes to data files. For clients connected to the ONTAP storage system, all the FabricPool data-tiering operations are completely transparent, and in case data blocks become hot again, they are copied back to fast media to the ONTAP. FabricPool is compatible with the

  • NetApp StorageGRID
  • Amazon S3 and Amazon Commercial Cloud Services (C2S)
  • Google Cloud
  • Alibaba object storage services
  • Azure Blob supported
  • IBM Cloud Object Storage (ICOS) in the cloud
  • IBM Cleversafe (on-prem object storage)

Other object-based SW & services could be used if requested by the customer and that service will be validated by NetApp. The FabricPool feature in FAS/AFF systems is free for use with NetApp StorageGRID external object storage. For other object storage systems such as Amazon S3 & Azure Blob, FabricPool must be licensed per TB to function (alongside costs for FabricPool licensing, the customer needs also to pay for consumed object space). While with the Cloud Volumes ONTAP storage system, FabricPool does not require licensing, costs will apply only for consumed space on the object storage. FlexGroup volumes and SVM-DR supported with FabricPool, also SVM-DR supported with FlexGroups.

FlashCache

NetApp storage systems running ONTAP can have FlashCache cards which can reduce read operations latency and allows the storage systems to process more read intensive work without adding any additional disk drives to the underlying RAID. Usually, one FlashCache module installed per controller, no mirroring performed between nodes and entire space from FlashCache used by a single node only, since read operations do not require redundancy in case of FlashCache failure, but chip-level data protection is available in FlashCache. If the system unexpectedly rebooted, read chance will be lost, but will restore over the time during regular node operation. FlashCache works on node level, by default accelerates any volumes on that node and only read operations. FlashCache caching policies applied on FlexVol level: system administrator can set cache policy on each individual volume on the controller or disable read cache at all. FlashCache technology is compatible with the FlexArray feature. Starting with 9.1 a single FlexVol volume can benefit from both FlashPool & FlashCache cache simultaneously.

FlexArray

FlexArray is NetApp FAS functionality allows to virtualize third-party storage systems, and other NetApp storage systems over SAN protocols and use them instead of NetApp’s disk shelves. With FlexArray functionality RAID protection must be provided with third-party storage array thus NetApp’s RAID-4, RAID-DP and RAID-TEC not used in such configurations. One or many LUNs from third-party arrays could be added to a single aggregate similarly to RAID-0. FlexArray is licensed feature.

NetApp Storage Encryption

NetApp Storage Encryption (NSE) is using specialized purpose-build disks with low level Hardware-based full disk encryption (FDE/SED) chip, some disks are FIPS-certified self-encrypted drives. NSE & FIPS drives compatible nearly with all NetApp ONTAP features and protocols but except for MetroCluster. NSE feature does overall nearly zero performance impact on the storage system. NSE feature similarly to NetApp Volume Encryption (NVE) in storage systems running ONTAP can store encryption key locally in Onboard Key Manager which stores keys in onboard TPM module or through KMIP protocol on dedicated key manager systems like IBM Security Key Lifecycle Manager and SafeNet KeySecure. NSE is data at rest encryption which means it protects only from physical disks theft and does not give an additional level of data security protection. In a standard operational and running ONTAP system, this feature does not encrypt data over the wire. When OS shuts disks down, they lose encryption key and becomes locked and if KeyManager not available or locked, ONTAP couldn’t boot. NetApp has passed NIST Cryptographic Module Validation Program for its NetApp CryptoMod (TPM) with ONTAP 9.2.

Continue to read

How ONTAP Memory work

Zoning for ONTAP Cluster

Disclaimer

Please note in this article I described my own understanding of the internal organization of ONTAP systems. Therefore, this information might be either outdated, or I simply might be wrong in some aspects and details. I will greatly appreciate any of your contribution to make this article better, please leave any of your ideas and suggestions about this topic in the comments below.

All product names, logos, and brands are property of their respective owners. All company, product and service names used in this website are for identification purposes only.